1.
Int. j. odontostomatol. (Print) ; 9(3): 489-492, dic. 2015. ilus
Article in English | LILACS | ID: lil-775476

ABSTRACT

The Resonance Frequency Analysis by Osstell® is used in the assessment of primary and secondary implant stability. The aim of this study was to determine its accuracy as a method of testing, checking its repeatability and reproducibility. A pilot study was performed whereby implants were placed in a cow rib to compare several ISQ measurements with the same SmartPeg transducer (repeatability), or with different SmartPegs (reproducibility). Statistical analysis of the data showed a high correlation of the ISQ values obtained in both assays, which suggests that Osstell®analysis can provide high repeatability and reproducibility.


El análisis de frecuencia de resonancia (AFR) por Osstell® se utiliza en la evaluación de la estabilidad primaria y secundaria del implante. El objetivo del presente estudio fue establecer la precisión del AFR mediante Osstell©, como método de prueba empleado en la determinación de la estabilidad implantaria. Se realizó un estudio experimental in vitro, en el que se colocaron implantes en una costilla de vaca y compararon diferentes mediciones del coeficiente de estabilidad del implante (ISQ) obtenidas sobre estos implantes con un mismo transductor SmartPeg (repetibilidad) o con diferentes SmartPegs (reproductibilidad). El análisis estadístico de los datos mostró una elevada correlación de los ISQ obtenidos en ambos ensayos, lo cual sugiere una reproductibilidad y repetibilidad elevada del análisis mediante Osstell.


Subject(s)
Humans , Dental Implants , Dental Implantation/instrumentation , Resonance Frequency Analysis , In Vitro Techniques , Reproducibility of Results
2.
Int. j. odontostomatol. (Print) ; 9(3): 483-487, dic. 2015. ilus
Article in English | LILACS | ID: lil-775475

ABSTRACT

The aim was to evaluate the differences of implant stability quotient (ISQ) between implants with external hexagon and Morse taper connectors. The study had a split mouth design, composed by 10 patients who received hybrid protocol prosthesis. In total, 40 implants (3.75 x 13 mm) were installed: on the right side, 20 external hexagon, and on the left, 20 Morse taper. After two years in function, the stability test was applied by using the MRI machine Osstell ISQ directly on the implants and on the abutments. Considering the measurements made on the implants, there were differences between HE and CM mesial (p= 0.011), lingual (p= 0.003) and distal (p= 0.006). Considering the measurements made on the abutments, there were differences between HE and CM on the buccal (p= 0.020) and lingual (p= 0.004). The trend and higher values are for the CM group. The values for Morse taper implants were always higher in a statistically significant manner, when compared to the external hexagon.


El objetivo fue evaluar las diferencias del coeficiente de estabilidad de implantes comparando los de conexión de hexágono externo (HE) y cono morse (CM). El estudio tuvo un diseño de boca dividida, siendo compuesta por 10 pacientes que recibieron protocolos protésicos de tipo hibrido. En total, 40 implantes (3,75x13 mm) fueron instalados: en el lado derecho, 20 implantes de hexágono externo y en el lado izquierdo, 20 implantes de cono morse. Después de dos años en función, la prueba de estabilidad fue aplicada utilizando una maquina MRI, Ostell ISQ directamente sobre los implantes y pilares. Considerando las medidas en los implantes, hubo diferencias entre los implantes HE y CM en mesial (p= 0,011), lingual (p= 0,003) y distal (p= 0,006). Considerando las medidas en los pilares, hubo diferenciasentre HE y CM en el sector bucal (p= 0,020) y lingual (p= 0,004). Los valores mas altos se obtuvieron en CM; los valores de las conexión tipo cono morse presentaron mayor estabilidad al comparase con los implantes de conexión de hexágono externo.


Subject(s)
Humans , Dental Implants , Dental Abutments , Dental Implantation , Resonance Frequency Analysis